Example (see the red line):
A flow of 25 liter/minute is desired. The discharge head is calculated to 30 mWC .We choose a T50.
It requires an air pressure of approx 5 bar and will consume approximately 0.2 Nm3 air per minute.
Find below ISO, ATEX and EC declaration of conformity for our products.
AODD pumps
EC declaration of conformity AODD pumps
ATEX declaration of conformity AODD pumps
Sanitary pumps
EC declaration of conformity Sanitary pumps
Pulsation Dampeners
EC declaration of conformity Pulsation dampeners
ATEX declaration of conformity Pulsation dampeners
CT pumps
EC declaration of conformity CT centrifugal pumps
ATEX declaration of conformity CT centrifugal pumps
ISO
Find technical info like certificates, how to understand the performance curves and chemical guide in this section.
The range of optional valves for sanitary pumps sizes T225 and T425 consists also of heavy duty ball cup valves. The ball valve cup is made in one piece with the valve seat. It is mounted on the pump with clamps therefore ensuring easy maintenance and cleaning. This option is a perfect solution when there is risk of damage to the valve seats form the product. If such situation is to occur there is no need to replace the whole manifolds or housings, just the valve cup what drastically reduces the spare parts cost.